Model HG2023A/HG2043A

 

Functions:

DC-20MHz/40MHz, two channels 4 traces

Horizontal system in Digital Coding Switch

Trigger Level locked, no need to adjust the trigger level to get the stable waveform

ALT trigger function, to observe the signals of different frequency from both channels

TV-trigger to observe the TV signals

Fast sweep 0.02uS/div

X-Y function

 
Specifications:

Vertical

Bandwidth

DC-20MHz(HG2023A) 40MHz (HG2043A)

Sensitivity

5mv/div5v/div (1-2-5 step in 10 steps)

Mode

CH1, CH2, ALT, CHOP, ADD

Input Impedance

1MΩ//30PF

Coupling

AC, DC, GND

Rising Time

17.5ns(HG2023A)  8.8ns(HG2043A)

Trace Separation

3div

Polarity Inversion

Only CH2

Horizontal

Sweep time

HG2023A: 0.2us/div0.2s/div (1-2-5, in 19steps) 

HG2043A: 0.1us/div0.1s/div (1-2-5, in 19steps)

Work Mode

X1, ALT, X10, X-Y

 Sensitivity

 Same as CH1

Trigger

Trigger Mode

AUTO, NORM, TV , SGL, Level Lock

Trigger Source

CH1,CH2, ALT,EXT

Trigger Coupling

AC ,DC,LINE,TV

Sensitivity

INT:5MHz 0.5div, 0-20MHz/40MHz:2div ,

EXT:5MHz .0.2V, 20MHz: 0.5V

 

Z Input

Sensitivity

Obviously change in 5V signal, positive signal lightness declines

Frequency range

DC-1MHz

Calibration

Signal

Waveform

Square

Amplitude

0.5Vp-p  ±3%

Frequency

1KHz ±3%

 CRT

Screen Size

10CM x 8CM

Power

Input voltage

220V ±10%

Frequency

50Hz

Power Consumption

40W

 

Size

327mm(w)*138mm(h)*443mm(I)